Heater parts removal and installation, Service – Airstream 1100 SERIES SINGLE FAN PNEG-339 User Manual

Page 33

Advertising
background image

33

HEATER PARTS REMOVAL AND INSTALLATION

b. Use a dependable brand of

high temperature pipe caulking

compound when assembling gas

connections. Apply only a light

coating onto male threaded end

of fittings.

c. Solenoid valves and gas regula-

tors are directional and must be

properly installed. Do not attempt

to connect gas solenoid valve by

applying force to the valve core

stem as it may ruin the unit.

d. Make sure all electrical wires are

properly connected. Refer to wiring

diagrams.

SERVICE

b. Disconnect gas solenoid valve

coils. Be sure to mark which one

goes where.

c. Lift pipe (with orifice, solenoid

valve and other parts attached),

straight up and remove from fan

heater housing. Orifice and other

parts can now be removed from

pipe train, if desired.

5.

Reassemble: To reassemble

parts, reverse the disassembly pro-

cedure and check the following:

a. Make sure all parts are thoroughly

cleaned and open.

Most heater parts can be removed

by simply identifying any attached

wiring. Then DISCONNECT the ob-

vious mounting parts.

1.

Flame sensor: DISCONNECT

the wire connector. UNSCREW

the flame sensor out of its

mounting bracket.

2.

Gas Solenoid valve coil: UN-

SNAP either the plastic cap, or

the metal clip on the gas valve,

and SLIDE the housing and coil off

the valve stem and body. Do

not energize the coil when it is

removed, as the coil may be-

come damaged due to exces-

sive current flow.

3.

Regulator and gas solenoid

valve(s): The gas regulator and so-

lenoid valve(s) are directional and

must be connected as indicated by

the markings near the port open-

ings. Make sure gas is shut off and

purged from the system before re-

moving parts.

Note: When installing a liquid

gas solenoid valve on LP models,

do not over tighten the connection

into the inlet side, as the inlet orifice

may become partially blocked.

4.

Main Gas Orifice: With fuel shut

off and gas purged from system,

proceed as follows:

a. Disconnect the plumbing sup-

port brackets from the pipe train.

This view of the dryer heater shows 1-gas solenoid valve coils and 2-gas

regulator and 3-gas solenoid valves.

1

1

2

3

3

Advertising