Service suggested lubricants – Airstream 1100 SERIES SINGLE FAN PNEG-339 User Manual

Page 30

Advertising
background image

30

SERVICE

SUGGESTED LUBRICANTS

Insulation Class

A & B
A & B
F & H

Consistency

Medium
Medium
Medium

Type

Polyurea
Polyurea
Polyurea

Grease

Shell Dolium R
Shell Dolium R
Shell Dolium R

Frame Type

215T & Smaller

254 & Larger

All

Note: All of the auger and meter-

ing roll bearings are lifetime lubri-

cated and do not require service

relubrication.

1.

Remove and CLEAN the gas

line strainers. Make certain gas

valves are CLOSED and that

gas is purged from the system

before attempting disassembly.

2.

Inspect the collector plate (at

the top of the burner casting)

and the burner cup for any ac-

cumulation of foreign material.

CLEAN if required. Foreign ma-

terial in the burner cup or cast-

ing will not burn out and will im-

pair burner operation.

3.

If required, inspect ignitor plug

and CLEAN the electrodes.

Use an ignition point file to remove

carbon and rust between the

electrode surfaces. Ignitor gap

should be about 1/8 inch.

4. Inspect flame sensor for pos-

sible damage or poor connec-

tions. Flame sensor wire must

be in good condition.

5.

Inspect and manually ROTATE

the top auger paddle assem-

bly. The paddle unit must rotate

freely without any indication of

sticking or binding.

6.

Inspect the top auger and bot-

tom auger drive lines for proper

adjustment and condition. Read-

just line tension as required.

Note: All of the auger and meter-

ing roll bearings are lifetime lubri-

cated and do not require service

relubrication.

7.

OPERATE dryer clean out le-

vers, and CHECK clean-out

hatch mechanism for proper op-

eration. With hatch open, in-

spect and remove any accumu-

lation of dirt, fines and foreign

material from the bottom au-

ger trough area.

Note: Do not allow high moisture

material to collect within the trough

area. It may adversely affect metal

parts.

8.

Inspect entire dryer for loose,

worn or damaged parts. Include

CHECK of auger flighting, me-

tering rolls and other internal

parts. CHECK that temperature

sensors within air plenum cham-

ber are secured within insulated

clamps, and do not chafe on

other metal parts.

9.

Make sure all dryer guards and

warning decals are securely in-

stalled. Guards should not inter-

fere with moving parts. If guards

or warning decals are missing,

contact your dealer for a free re-

placement.

10. TEST FIRE the dryer several

weeks ahead of the drying sea-

son. CHECK for possible gas

leaks. (See page 16 for burner

test fire.)

Remove the Blue Burn Optimizer Cone. Inspect 1-collector plate, 2-burner

cup, 3-ignitor plug and electrodes and 4-flame sensor on the heater.

4

2

1

3

Advertising