DRYER START UP

button. The controller will start

all the dryer components in their

proper order. If any of the se-

lected switches are improperly

positioned for staged batch dry-

ing, the display will indicate the

proper switch position, and will

not allow the dryer to operate

until the position of the switch is

corrected.

14. To shutdown the dryer, CLOSE

the FUEL SUPPLY valve at the

fuel tank or fuel source. If the

burner is operating, let the dryer

run out of fuel causing an auto-

matic shutdown due to a loss of

flame. CLOSE the FUEL VALVE

at the dryer, and press the dryer

POWER STOP button. Turn

OFF the dryer's main CIRCUIT

BREAKER located on the front

of the power panel. Turn OFF

the MAIN main POWER SUP-

PLY to the dryer.

15. In case of an emergency press

the dryer POWER STOP button.

The burner, fan and all augers

will stop immediately.

start automatically during the

unload cycle of the dry-cool-

unload mode, along with any

grain handling equipment that

is wired to the dryer. The

speed at which the metering

rolls operate during the unload

cycle is adjusted by using the

HIGH SPEED METERING roll

dial. Turning the dial clockwise

will INCREASE the grain dis-

charge rate, and counterclock

wise will DECREASE the dis-

charge rate.

12. To control the length of the dry

cycle using only the dry time

setting programmed into the

system, turn the MOISTURE

CONTROL setting to OFF. To

use the automatic moisture con-

trol so that the dry time is deter-

mined, not only by the dry time

setting, but also by the moisture

content of the drying grain, turn

the MOISTURE CONTROL

switch to ON.

13. To start the drying operation

push the dryer POWER START

9. If the dryer is being operated in

all heat, turn the FAN switch to

ON. In this position the fan will

run continuously during the dry,

cool and unload stages of the

staged batch operation. If the

dryer is being operated in the

dry and cool mode, the preferred

position for the FAN switch is the

ON position, so the fan will run

continuously. If desired, the fan

can be turned off during the un-

load cycle of the dry-cool-unload

sequence by turning the FAN

switch to AUTO.

10. If the dryer is being operated in

all heat, turn the HEATER

switch to ON. The burner will

operate whenever the fan is

operating. If the dryer is being

used in dry and cool, turn the

HEATER switch to AUTO and

the burner will automatically

shutdown during the cooling and

unloading cycles.

11. Turn the UNLOAD switch to the

1 SPEED position. The bottom

auger and metering rolls will

Fan Setting

Auto

Auto

On

On

Fan Function

Fans stay on during dry and cool

cycle only

Fans stay on during dry and cool

cycle only

Fans are on continuously

Fans are on continuously

Heater Function

Burners stay on during dry timer cycle

only

Burners stay on during dry and cool

Burners are on continuously

Burners shut down at the end of the

dry cycle

Heater Setting

Auto

On

On

Auto

FAN & HEATER SWITCH SETTINGS

At the end of the dry cycle in staged batch, the fans and heaters will continue running if in the Auto-Auto setting, until the preset tempera-

ture on the moisture control thermostat is reached.