51

QUICK REFERENCE GUIDE

ELECTRONIC MONITORING CONTROL SYSTEM

Important! To activate the controller

after turning on the control power,

press the reset button.

To set the dry, cool, unload and out

of grain timers:

Press the dry, cool, unload or

out of grain button

Press the modify button

Press the increase or decrease

button to get desired setting

Press the enter button when

desired setting is reached

To set the load and unload delays:

Press the load or unload button

Press the modify button

Press increase or decrease

button to get desired setting

Press the enter button when

desired setting is reached

Pressing the increase and decrease

buttons simultaneously will access

the following programming features:

Safety circuit shutdown log

Dryer model number

Fan delay

BPH factor

Fill auger options:

a. Center fill auger

b. End fill auger

Metering roll monitor disabling

feature

Air switch disabling feature

These features are accessed se-

quentially as listed above. Press the

increase or decrease buttons to

change a setting. Press the enter

button to move from feature to fea-

ture.

Pressing and holding the reset but-

ton for five seconds will access the

following programming features:

Calendar year setting

Calendar month setting

Calendar day setting

Clock hour setting

Clock minute setting

Bushel counter reset

Batch counter reset

These features are accessed sequen-

tially as listed above. Press the in-

crease or decrease buttons to

change a setting. Press the enter but-

ton to move from feature to feature.

To change the marquee on the

LCD display:

Press and hold the modify button

while turning on the control power

Press the increase or decrease

button to change a character

Press the unload button to move

the cursor to the right

Press the dry button to move the

cursor to the left

Press the cool button to delete

a character

Press enter when the desired

marquee is displayed

To reset the computer to the original

default setting, turn off the computer,

press and hold the green AUX 1 but-

ton and turn on the computer.

NOVRAM will appear on the LCD dis-

play. The year, date, time and min-

utes may be changed now, and the

shutdown history may also be cleared.

Note: If the history is cleared the

dryer model number must be reset or

only the bottom fan will operate (if so

equipped).