Dryer control panel – Airstream 1100 SERIES SINGLE FAN PNEG-339 User Manual

Page 12

Advertising
background image

12

DRYER CONTROL PANEL

When operating the dryer the LCD

display will show the DRYER MODE

OF OPERATION on the first line, the

BUSHELS PER HOUR or the ME-

TERING ROLL RPM on the second

line and the TOTAL BUSHELS dried

on the third line. By pressing the

BPH/RPM/TOTAL BU button the

second line will alternate between

the METERING ROLL RPM's or the

BUSHEL PER HOUR rate. The TO-

TAL BUSHELS DRIED reading is

the total since the bushel counter

was last reset. To reset the

BUSHEL COUNTER, press and

hold the RESET button for five sec-

onds. Press the ENTER button

through the date and time settings

and then follow the instructions dis-

played on the LCD for resetting the

counter.

In the STAGED BATCH DRY-

ING MODE the first line of the LCD

display tells which TIMER is being

used, and the second line switches

between TOTAL BATCHES, UN-

LOAD RPM or TOTAL BUSHELS.

The third line indicates TOTAL DRY

TIME and the fourth line is TIME

REMAINING on the TIMERS.

SETTING THE LOAD (20)

AND UNLOAD (21) DELAYS

The LOAD DELAY is used to delay

the starting of the load auger when

the dryer is unloading to prevent the

load auger from starting and stop-

ping. The UNLOAD DELAY is used

to control the amount of time the un-

load auger runs after the metering

rolls stop to allow for auger

cleanout. Both the LOAD and UN-

LOAD DELAYS are set using the

same procedure as the TIMERS.

The AUX1 and AUX 2 DELAYS are

presently not being used.

DRYER SAFETY CIRCUIT

The Electronic Monitoring Control

System continuously checks all

safety circuits on the dryer, and will

automatically shut the dryer down

should a problem occur. The cause

of the dryer shutdown will be dis-

played on the LCD display, and a

beeper will sound on the controller.

To restart the dryer after a safety

shutdown, first correct the reason for

the shutdown, and then press the

DRYER POWER STOP button to re-

set the circuit. Press the START

button.

The Electronic Monitoring

Control System stores in its

memory the time, date and cause for

the last 25 dryer safety shutdowns.

To review this information hold the

RESET button in for five seconds.

The procedure for reviewing the

safety circuit shutdown log will be

displayed on the LCD display.

UTILIZING THE

BUSHEL COUNTER (22)

The Airstream Electronic Monitoring Control System showing different LCD displays.

Advertising