Appendix B. Understanding TR-08

B-2

TSU 600 User Manual

61202076L1-1

The following table explains what conditions trigger alarms and how
alarms are processed when received by the TSU 600.

Table B-1.

Alarm Conditions

Name

Explanation

FELP

When the TSU 600 receives a FELP alarm, it will loop
the incoming data directly to the outgoing data. LINE
ON is placed in history. The alarms and loopback are
cleared when FELP is no longer received.

Loss of Data

The TSU 600 will send MINOR ALARM and the A
SHELF ALARM

for 2.5s when it quits receiving the

data link on the T-Span. It will also report TR-08 DL
Down in the history. After 2.5s, MAJOR ALARM, A
SHELF ALARM

are sent across the Data Link.

OOF

The TSU will send MINOR ALARM and A SHELF
ALARM

upon receiving an out-of-frame condition.

TR-08 DL Down

and RED ALARM are declared in

history for severe framing errors. After 2.5s, MAJOR
ALARM

, A SHELF ALARM are sent across the Data

Link.

Loss of Signal

The TSU 600 will send MINOR ALARM and the A
SHELF ALARM

for 2.5s when it quits receiving a

signal from the far end. It will also report TR-08 DL
Down

and LOS in the history. After 2.5s, MAJOR

ALARM

, A SHELF ALARM are sent across the Data

Link, and RED ALARM is declared in history.

BPVs

BPVs that are received at a rate greater than the
threshold set under TR-08 options, will cause
MINOR ALARM

and A SHELF ALARM to be sent

on the DL. If the BPVs remain above the threshold for
2.5s, the TSU 600 will send MAJOR ALARM and on
the DL. No events are placed in history.

Protection
Line Switch

The TSU will not respond to this alarm.