Chapter 3. Operation

3-12

TSU 600 User Manual

61202076L1-1

T-Watch PRO/EIA-232 Connection

To set up the TSU 600 to work with T-Watch PRO over a direct EIA-232
connection, the following steps are required:

SNMP

The ADTRAN TSU 600 supports the Simple Network Management Pro-
tocol (SNMP) through the chain-in (SLIP) interface or 10BaseT interface
(600e only). See Appendix B, Understanding SNMP for detailed informa-
tion.

To use SNMP with the TSU 600, do the following:

Step

Action

1

Set the

Unit ID

and the

Passcode

using the Front Panel.

See Unit ID on page 6-3 and Change/Set a Passcode on page
6-3
for more details.

2

Set the

Control Port rate

to the same setting as the PC

Com port.

3

Connect the

PC Com port

to the

Chain-In port

on the

TSU 600 using the DB25 to modular adapter and 6-foot
modular cable.

4

Follow the installation instructions for T-Watch PRO to
start the program and connect to the unit.

Step

Action

1

Set Control Port to

SLIP

for Chain-In Port or

Normal

for 10BaseT

(600e only).

2

Set the IP address, default gateway, and subnet mask through the
front panel.

The default gateway and subnet mask are not used in SLIP mode.

3

Load the appropriate MIB browser into the Network Management
Station (available on the ADTRAN webpage at http://www.adt-
ran.com)

. The MIB browser issues SNMP gets/sets to the TSU 600.