Chapter 5. Configuration Menu

61202076L1-1

TSU 600 User Manual

5-5

DTE Timing

The DTE is the source of timing. The TSU 600 uses the incoming DTE
clock to determine the transmission timing. This is typically used in ap-
plications where it is necessary to have the DTE as the primary clock
source (such as limited distance line drivers). See Figure 5-3.

The DTE source timing is restricted from use when a secondary interface
is used at the same time.

Figure 5-3.

DTE Timed Clock Source

U-BR1TE (Slot 1)

The timing mode selection U-BR1TE (Slot 1) works much like DTE tim-
ing except that the clock is derived from the U interface.