3-11

IM 04P01B01-17E

Using

the
RS-422A/485

Communication

Interface

(/C3
Option)

1

2

3

4

5

6

App

Index

Input Register Data

33001

Alarm status of the computed data of CH0A

33002

Alarm status of the computed data of CH0B

33003

Alarm status of the computed data of CH0C

33004

Alarm status of the computed data of CH0D

33005

Alarm status of the computed data of CH0E

33006

Alarm status of the computed data of CH0F

33007

Alarm status of the computed data of CH0G

33008

Alarm status of the computed data of CH0J

33009

Alarm status of the computed data of CH0K

33010

Alarm status of the computed data of CH0M

33011

Alarm status of the computed data of CH0N

33012

Alarm status of the computed data of CH0P

33013

Alarm status of the computed data of CH1A

33014

Alarm status of the computed data of CH1B

33015

Alarm status of the computed data of CH1C

33016

Alarm status of the computed data of CH1D

33017

Alarm status of the computed data of CH1E

33018

Alarm status of the computed data of CH1F

33019

Alarm status of the computed data of CH1G

33020

Alarm status of the computed data of CH1J

33021

Alarm status of the computed data of CH1K

33022

Alarm status of the computed data of CH1M

33023

Alarm status of the computed data of CH1N

33024

Alarm status of the computed data of CH1P

• Registers corresponding to models with the /M1 computation function option.
• The values are the same as those of the alarm status of the measured data.
• Valid channels vary depending on the device. An error response (code 2) occurs when an

invalid channel is read.

Input Register Data

36001

List of alarms of the measured data of CH01 to CH04

36002

List of alarms of the measured data of CH05 to CH08

36003

List of alarms of the measured data of CH09 to CH12

36004

List of alarms of the measured data of CH13 to CH16

36005

List of alarms of the measured data of CH17 to CH20

36006

List of alarms of the measured data of CH21 to CH24

36007 to 36020 Always 0
36021

List of alarms of the computed data of CH0A to CH0D

36022

List of alarms of the computed data of CH0E to CH0J

36023

List of alarms of the computed data of CH0K to CH0P

36024

List of alarms of the computed data of CH1A to CH1D

36025

List of alarms of the computed data of CH1E to CH1J

36026

List of alarms of the computed data of CH1K to CH1P

1 register (1 word)

Level 1

Level 2

Level 4

Level 3

The bit is set to 1

when an alarm occurs.

Example of Register 36001

CH4

CH3

CH2

CH1

• Registers 36001 to 36026 can be read with a single command.
• Bits corresponding to invalid channels are fixed to “0.”

3.4 Modbus Slave Specifications