Restoring typical zoning, Accessing web tools for advanced management, Making ezswitchsetup your default switch manager – Brocade EZSwitchSetup Administrator’s Guide (Supporting 300, 5100, 5300, 6505, 6510, 6520, 7800, 7840, and VA-40FC) User Manual

Page 60

Advertising
background image

Restoring Typical Zoning

If you have modified your zoning configuration and want to reset the configuration back to the default
Typical Zoning configuration, use the following procedure.

1.

Click Restore Default Typical Zoning under Zoning in the Tasks panel.

2.

Click Yes in the confirmation window.

When this task is complete, the matrix in the Zone Access Map for Devices page is
automatically updated to reflect the changes.

Accessing Web Tools for advanced management

From the Switch Manager, you can launch Web Tools, which provides more extensive switch
management functions for more experienced users. Refer to the Web Tools Administrator’s Guide for
information on the Web Tools interface.

To launch Web Tools, ensure that you have completed all Switch Manager tasks and then click
Advanced Management under Miscellaneous in the Tasks panel. The Switch Manager session will
be closes. Any editing in Switch Manager that has not been applied is lost.

After entering Web Tools, you must log in again to manage the switch.

You cannot return to EZSwitchSetup Switch Manager unless you close and re-open your browser
window and relaunch EZSwitchSetup.

Making EZSwitchSetup your default switch manager

If you want to be sure that the EZSwitchSetup Switch Manager is launched as the default switch
management program from your browser instead of Web Tools, complete the following steps.

1.

Log in to the switch.

2.

Enter the configure command and type yes or y to display Web Tools attributes, as shown in the
following example.

switch:admin> configure

Not all options will be available on an enabled switch.

To disable the switch, use the "switchDisable" command.

Configure...

System services (yes, y, no, n): [no]

ssl attributes (yes, y, no, n): [no]

rpcd attributes (yes, y, no, n): [no]

webtools attributes (yes, y, no, n): [no] y

Web Tools attributes are displayed.

3.

Type yes or y for the Basic User Enabled attribute to make the EZSwitchSetup Switch Manager
start by default from your browser rather than Web Tools, as in the following example.

Basic User Enabled (yes, y, no, n): [yes] y

If no or n is specified, Web Tools is launched. Note that no is the default value.

Restoring Typical Zoning

58

EZSwitchSetup Administrator’s Guide

53-1003129-01