HATZ Diesel 1B 50 User Manual

Page 50

Advertising
background image

Symbol

Maintenance in-
terval

Maintenance activity/check

Chapter

Every 8-15 oper-
ating hours or ev-
ery day before
starting

Check the oil level.

7.8 Checking the

oil level and add-

ing oil if necessa-

ry, page 44

Check the engine oil level in
the bottom section of the oil
bath filter and examine the oil
for contamination. Change the
oil if it is sludgy.

8.2.7 Maintaining

the oil bath filter,

page 60

In models with a cyclone pre-
cleaner: remove the dust trap.

Check the intake area of the
combustion and cooling air.

8.2.3 Checking

the intake area,

page 51

Check the air filter mainte-
nance indicator.

8.2.12 Maintain-

ing the dry air fil-

ter, page 73

Check the water separator.

7.7 Checking the

water separator,

page 43

250h

Every 250 operat-
ing hours

Maintain the oil bath filter.

8.2.7 Maintaining

the oil bath filter,

page 60

Change the engine oil.

8.2.4 Change the

engine oil,

page 53

Check and adjust the tappet
clearance (not in models with
an automatic valve lash adjust-
ment).

8.2.6 Check and

set the tappet

clearance,

page 56

Clean the cooling air area.

8.2.8 Clean the

cooling air area,

page 61

Check the screw connections.

8.2.9 Check the

screw connec-

tions, page 64

Clean the exhaust screen.

8.2.10 Clean the

exhaust screen,

page 64

Maintenance

1B20, 1B27, 1B30, 1B40, 1B50

50

Operator's Manual 1B20-1B50

HATZ

Advertising