Type of fault

Possible causes

Remedy

Chapter

Machine is not un-
coupled.

If possible, sepa-
rate the engine
from the machine
by uncoupling it.

Fuel filter is clog-
ged.

Change the fuel fil-
ter.

8.2.11
Changing
the fuel fil-
ter, page 68

With automatic
electrical switch-off
mechanism (addi-
tional equipment)


Stop signal from
monitoring ele-
ments that are as-
sociated with the
automatic switch-
off.

Identify the trigger-
ing monitoring ele-
ment and eliminate
the source of the
fault, or contact the
HATZ service sta-
tion.

Monitoring element
for:
▪ Oil pressure too

low.

▪ Engine tempera-

ture too high.

Check the engine
for:
Engine oil
filling level
Contamination of
the cooling air
guides or another
impairment of the
cooling system.

7.8 Check-
ing the oil
level and
adding oil if
necessary,
page 44
8.2.8 Clean
the cooling
air area,
page 61

Faulty AC alterna-
tor.

Contact the Hatz
service station.

Fault signal from
the overvoltage
and polarity protec-
tion system in the
voltage regulator:
▪ Battery and/or

other cable con-
nections are in-
correctly con-
nected.

▪ Loose cable con-

nections.

Check the electri-
cal equipment and
their components.

3.2.4 Elec-
trical equip-
ment,
page 18