CAUTION

Danger of later engine damage.
The monitoring components (oil pressure, charge control and
engine temperature) are deactivated in emergency operation.

▪ The oil level must be checked before the emergency opera-

tion phase.

NOTICE

i

If the emergency operation mode is used, the risk transfers to
the operator (the Motorenfabrik HATZ does not accept liabili-
ty in this case
).

▪ Immediately after the emergency operation phase, deter-

mine the cause of the fault.

▪ Have the Hatz service station supply the emergency start

lever with a new lead seal.

Overview

Pos.

Designation

1

Fuel shutoff valve (additional equipment)

2

Emergency start lever

Procedure

Step

Activity

1

Using suitable pliers, turn the emergency start lever (2) coun-
terclockwise by at least 90° (seal wire tears).
The emergency start level is now located in the start position,
and the shutoff valve (1) is mechanically unlocked.

Faults

1B20, 1B27, 1B30, 1B40, 1B50

84

Operator's Manual 1B20-1B50

HATZ