Seed Hawk Air Drill Monitor 2008 User Manual

Page 13

Advertising
background image

Seed Hawk Air Drill Monitor

SeedHawk Manual 01.doc

Not Released

Page 11

When the 400 feet has been driven, the operator can press the MODE key once again to stop
the pulse counting. This will bring up a standard SAVE screen. To save, select Y and then
press and hold OK until after the long beep. However, if the new count is less than 50, the
existing count is not replaced. To discard the changes, select N and then press the OK key.

3.3 Fan

DISPLAY 1 FUNCTION

RANGE

COMMENTS

PULSES

Pulses per revolution
on shaft sensor

0 to 4

Set to 0 to disable alarm
monitoring for this fan.

Default pulses/rev: 2

LO FAN

Low fan alarm point

1000 – HI
FAN

10 rpm increment/decrement.

Default alarm point: 1500 rpm

HI FAN

High fan alarm point

LO FAN -
9990

10 rpm increment/decrement.

Default alarm point: 5500 rpm

3.4 Shaft And Bin Level

DISPLAY 1 FUNCTION

RANGE

COMMENTS

PULSES

Pulses per revolution
on shaft sensor

0 to 99

Set to 0 to disable alarm
monitoring for this shaft.

Default pulses/rev: 27

LOSHFT

Low shaft alarm

0 to 999.5 0.5 rpm increment/decrement

Default alarm point: 0.5 rpm

WT/REV

Weight per Rev

0.000 to
5.000

Default weight per rev: 0 lb/rev

LEVEL

Alarm point for low bin
level

0 to 100
%

Set to 0 to disable alarm
monitoring for this bin.
Default level: 20%

When a shaft is disabled, the associated bin level will still function normally. To disable a bin
alarm, the LEVEL setting for that bin must be set to 0.