5.2

General Electrical Specification

Nominal Power Supply:

12 Vdc

Supply Current:

3A or less, depending on the number and type of
sensors attached.

Fusing:

The unit is protected with a polyswitch, which acts like a
resetting 3.75 A fuse

Power Supply Range:

10.5 to 16 Vdc

Overvoltage protection:

Survive 24 Vdc for up to five minutes.

Transient Protection:

The monitor and the attached sensors, when properly
installed, will not be damaged by the transients present
in the mobile agricultural environment (per ASAE EP455
5.11 and 5.12).

Power connection:

2-pin Packard WeatherPak

A - +12 Vdc

B - GND

Signal connection:

3-pin Packard WeatherPak

A - +12 Vdc

B - GND

C - Data

Radar Connection:

AMP CPC connector

1 - GND

2 - Radar signal

3 - +12 Vdc to RADAR

4 - Radar present