PUMP ELEcTRIcAL INSTRUcTIONS

Wire Size chart

distance From

Motor To Fuse

Box, Meter or

Electrical Outlet

Minimum copper Wire Size chart (Gauge)

Single Phase Motors

1 hP

1-1/2 hP

2 hP

115 Volt 230 Volt 115 Volt 230 Volt 115 Volt 230 Volt

0-50 Ft.

50-100 Ft.

100-150 Ft.

150-200 Ft.

200-300 Ft.

Fuse Size (Amps)

12

8

*

*

*

20

14

14

12

12

10

15

12

10

8

*

*

20

14

14

12

12

10

15

12

10

8

*

*

20

14

14

12

10

10

15

(*) Not economical to run in 115 V; use 230 V

cAUTION

ELEcTRIcAL ShOcK MAY OccUR

All wiring should be performed by a qualified electrician in accordance with the National Electric Code and local

electric codes.

ELEcTRIcAL ShOcK MAY OccUR

Connect the pump to a separate electrical circuit with a dedicated circuit breaker. Reference the wire size chart

below for proper fuse size.

ELEcTRIcAL ShOcK MAY OccUR

Protect the power cable from coming in contact with sharp objects.

PROdUcT dAMAGE MAY RESULT

Make certain that the power source matches the pump requirements. This pump has a dual voltage

motor and can run on 115 V or 230 V. This pump is wired from the factory to run on 230 volts; refer to

page 17 if you want to change the pump to run on 115 volts.

ELEcTRIcAL ShOcK ALERT.

Under-size wiring can cause motor failure and even fire. Use proper wire size specified in

the wire size chart on page 15.

ELEcTRIcAL ShOcK ALERT.

Replace damaged or worn wiring cord immediately.

ELEcTRIcAL ShOcK ALERT.

Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces,

or chemicals.

ELEcTRIcAL ShOcK ALERT.

The pump must be properly grounded using the proper wire cable with ground.

ELEcTRIcAL ShOcK ALERT.

Always disconnect pump from electricity before performing any work on the motor.

WARNING

NOTE: This pump can be used with a variety of controls, including a pump start relay, pressure switch

with tank and indexing valve. See control manufacturer’s instructions for details.