PUMP PRIMING ANd STARTUP

IL1278

Priming Plug

with Pressure

Gauge

Outlet Pipe

Inlet

Pipe

Air Relief Plug

IL1279

Priming Plug with

Pressure Gauge

Air Relief Plug

IL1280

Air Relief

Hole

1

2

3

cAUTION: All pumps must be primed by

filling the pump cavity with water before they

are first operated. This may take several gallons

of water, as the entire inlet line will be filled in

addition to the pump cavity. The longer the inlet

line, the more water is required for priming.
1. Disconnect the 1-1/2 in. outlet union and

separate the pipe.

2. Remove the air relief plug on top of pump

and the 1-1/4 in. priming plug with pressure

gauge or plug. Refer to Pump Preparation

Step 5.

3. Slowly fill pump cavity until water comes out

of air relief hole on top of the pump.

Advertising