5

Vertical Lift

Vertical lift is the vertical distance from the

lowest level of the water to the pump intake. The

pump will move water as long as the pump is

within 25 vertical feet of the water source.
horizontal distance

The horizontal distance is the horizontal

measurement between the pump inlet and the

water source. This distance may affect the ability

of the pump to operate. If it is over 150 feet, call

customer service at 1-800-742-5044.
Pipe And Fittings

Use galvanized steel or NSF PW Schedule 40

PVC pipe and fittings. This material is designed

for water pressure and will seal against air

and water under pressure. Do Not Use: DWV

fittings, as these are designed for drains without

pressure and will not seal properly.

cAUTION: The entire system must be

air and water tight for efficient operation and to

maintain prime.
Wire Size:

The wire size is determined by the distance

from the breaker box to the pump motor, and

the horsepower rating of the motor. See the wire

chart on page 15 for proper wire size.

GENERAL PUMP INFORMATION

Water Level

25 ft.

max

Vertical

Lift

Outlet Pipe

Inlet

Pipe

Discharge to

Sprinkler System

Inlet pipe to water

Pipe

Support

60 ft. max.

Motor Cover

Foot

Valve

1-1/2 in. Discharge

2 in.

Suction

3

4

cAUTION: Dry-fit entire assembly to ensure proper fit before gluing or taping parts.

cAUTION: Follow all proper gluing procedures as specified by the glue manufacturer. Always glue

in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings

cAUTION: Use thread tape and a thread paste compound on all male threads except for the

unions. Tighten securely with a wrench and add another 1/4 turn to ensure proper seal.