PUMP ELEcTRIcAL INSTRUcTIONS

b. Pull the red wire with the female flag

connector from the “B” terminal. Place it

to the right on the L2 terminal space post.

c. Reinstall the rear motor cover.

A

B

L2

L1

GRAY

RED

7b

7c

7. For 115 volts service, change the following

wires on the terminal board:

a. Using a pair of needle nose pliers,

pull the gray wire with the female flag

connector from the “B” terminal spade

post. Place it to the left on the “A”

terminal space post.

A

B

L2

L1

GRAY

RED

7a