IMPORTANT: If the pump fails to prime within five minutes:

7. Turn the power off at the break box. Check all pipe connections for leaks, making sure all

connections are water and air tight. Check the inlet pipe for any sagging, making sure the inlet pipe

is in a straight line to the pump. Watch for leaks or a milky color in the discharged water, which

indicated an air leak. Re-prime if necessary, following steps 1 through 6. Reset breaker at the

breaker box.

IMPORTANT: If the pump hums instead of pumping or turns off repeatedly, shut pump off

immediately. Check voltage. Pump is wired to run on 230 volts. If the pump cuts out or stops, you may

be attempting to connect to 115 volts. See PUMP ELECTRICAL INSTRUCTIONS Page 17 to see how

to correctly change the motor voltage to 115 volts.

SPEcIFIcATIONS

PUMP PRIMING ANd STARTUP

MOTOR DATA CHART - HSP SERIES

HP

Phase

Volts

Code

Letter

Max

Amps

Locked

Rotor

Amps

1

1
1

115
230

H

17.6

8.8

62.0
31.0

1-1/2

1
1

115
230

G

18.00

9.00

72.0
36.0

2

1
1

115
230

G

21.00
10.50

108.0

54.0

PERFORMANCE

Model

HP

Suction

Lift (FT)

Capacity - U.S. Gallons per Hour

Discharge Pressure (PSI)

Suction

Pipe

Discharge

Pipe

15

20

25

30

35

40

HSP10P1

1

10

15

20

25

3420

2820

2640

1440

3120

2640

2520

1380

2700

2220

2160

1320

2100

1800

1500

1020

1200

600

480

300

0

0

0

0

2"

1-1/2"

HSP15P1

1-1/2

10

15

20

25

4092

3780

3366

2520

3894

3660

3300

2490

3564

3420

2838

2430

3168

2970

2640

2280

2508

2310

1848

1452

1716

1188

600

0

2"

1-1/2"

HSP20P1

2

10

15

20

25

4309

3894

3557

2640

4172

3780

3488

2599

4036

3600

3420

2531

3625

3300

3215

2430

3078

2772

2531

2220

2462

2112

1573

720

2"

1-1/2"

Advertising
This manual is related to the following products: