For a front approach, where the depth
of the alcove is equal to or less than 24
inches (610 mm), the required clear
floor space is 30 inches by 48 inches
(760 mm by 1220 mm).

For a side approach, where the depth of
the alcove is equal to or less than 15
inches (380 mm), the required clear
floor space is 30 inches by 48 inches
(760 mm by 1220 mm).

Figures 4d. Clear Floor Space in
Alcoves.

For a front approach, if the depth of the
alcove is greater than 24 inches (610
mm), then in addition to the 30-inch
(760 mm) width, a maneuvering
clearance of 6 inches (150 mm) in width
is required.

For a side approach, where the depth of
the alcove is greater than 15 inches (380
mm), then in addition to the 48-inch
(1220 mm) length, an additional
maneuvering clearance of 12 inches
(350 mm) is required.

Figures 4e. Clear Floor Space in
Alcove.

4.2.6

Side Reach. If the clear floor space allows parallel approach by a person

in a wheelchair, the maximum high side reach allowed shall be 54 inches (1370
mm) and the low side reach shall be no less than 9 inches (230 mm) above the floor
(Fig. 6(a) and 6(b)). If the side reach is over an obstruction, the reach and clearances
shall be as shown in Fig 6(c).