To ensure that the temperature around the unit is maintained during cold weather,
it’s important that the wall opening is prepared correctly. Any cavity in the wall
should be sealed to provide a flush surface. After the control panel trim is installed,
a good weather seal is needed between the exterior wall and the trim. A
suitable water -resistant sealant product is required around the periphery of the
control panel trim. There are also products that are color tinted to closely match the
trim color.

* IMPORTANT *

SEAL THE CONTROL PANEL TRIM TO THE EXTE-
RIOR WALL WITH A WATER-RESISTANT SEALANT
TO PREVENT WATER INTRUSION. DO NOT SEAL
AROUND THE BOTTOM OF THE FASCIA! SMALL
DRAIN HOLES ARE LOCATED ON THE UNDERSIDE
THAT MUST BE CLEAR.

Figure 10. Control panel trim sealed.

Drain hole locations