42

RT2000 S

ERIES

- S

ITE

P

REPARATION

AND

I

NSTALLATION

G

UIDE

TEMPERATURE/HUMIDITY

1.

The ATM will operate over a
range of temperatures and hu-
midity. Generally, these pa-
rameters must fall within the fol-
lowing ranges:

Temperature (Interior)

10°C - 40°C

50°F - 104° F

Relative Humidity

20% - 80%

(Non-Condensing)

Temperature (Exterior)

AC POWER REQUIREMENTS

2.

Ensure the following AC power
requirements are met:

Current (Max)

5.05A @ 120V

2.01A @ 240V

Voltage

90V - 136V @ 50/60 Hz

198V - 257V @ 50/60 Hz

Power Consumption (Idle)

2.0A @ 115 VAC at 60 Hz

1.0A @ 230 VAC at 50 Hz

Isolated Ground. An equipment
grounding conductor that is insulated
from the conduit or raceway and all
other grounding points throughout its
entire length. The only points of elec-
trical connection will be at the duplex
outlet and service panel ends of the line.

DEDICATED TELEPHONE

3.

Ensure the following telephone-
line requirements are met:

Dedicated line. The telephone line ser-
vicing the ATM will not be a “party”
line or any other shared type connec-
tion.
Proximity to Interference Sources.
The telephone line must not be in close
proximity to “noisy” devices that could
induce interference into the ATM com-
munications channel. See the next sec-
tion for addtional information on “in-
terference sources.”

Dedicated source. The ATMs AC
power feed will be a dedicated line to
which no other electrical devices are
connected. The ATM power line will be
wired for a single “duplex”-style outlet
and connected directly to the AC ser-
vice panel.

Power Consumption (Max Load)

606 Watts @ 120V

482 Watts @ 240V

When installing an ATM, some general environmental precautions
need to be considered. Evaluate the location where the ATM will be
installed. To help ensure proper operation of the ATM, ensure the
environmental criteria listed are met.

-35°C - 50°C

-30°F - 122°F

Relative Humidity

20% - 100%

* IMPORTANT *

The phone line used for the ATM
shall not be shared with any other
device!

* IMPORTANT *

AC power for the terminal should
come from a dedicated source with
an isolated ground.