(7) Setting minimum master value



With “MIN M.” shown on the alphanumeric display, press . The current

minimum master value is shown. Press or to enter the new minimum

master value.

Fig. 9-15. Entering minimum master value.



Press to determine the new minimum master value. The next step is

storing the set values, and “END” is shown on the alphanumeric display.

Fig. 9-16. Determining minimum master value.

‘

When the minimum master value is equal to or greater than the maximum master

value, “ERR MAS” is shown on the alphanumeric display, the set value returns to

the previous value, and the instrument returns to the condition in step  above.

Again enter the new minimum master value.

2

1

3

S E T

MAS

ENT

RST

SET

MAS

MIN M.

Press

2

1

3

S E T

MAS

ENT

RST

SET

MAS

9.005

Decrements
minimum
master value

Increments
minimum
master value

2

1

3

S E T

MAS

ENT

RST

SET

MAS

9.025

Determines

2

1

3

S E T

MAS

ENT

RST

SET

MAS

END