DIGITAL AIR MICROMETER USERS MANUAL (Second Edition)

4

CHAPTER 1

INTRODUCTION

Thank you for purchasing the Digital Air Micrometer (DAG2000).
This manual is explained such that even first time users of the Air Micrometer will be able to use the
abundant functions of this product efficiently. Please read the manual thoroughly to use this product
well.

1.1 Outline

• This product is a measurement device that detects the air pressure changes based on the

dimensions of the measurement subject through sensors, and makes judgments based on digital
dimension indicators and lamps.

• This product is a comparison measurement device.

Measure the master for reference and then do measurements. With regular master calibrations,
good precision measurements are possible.

• This product judges independently if the measurement value is OK or NG.

Judgment result display can be quickly distinguished through the indicator color of the main
display and judgment LED.
Also, regular master calibrations can be done through the panel key.

1.2 Merits

① Judgment result (OK or NG) of measurement value can be distinguished through the number and

lamp color.

② Measurement value unit display can be switched (

µm or mm) by changing the settings.

③ Master calibration is easy.
④ Peak

measurement

[Optional]

• +PEAK, -PEAK, TIR(=+PEAK-(-PEAK)), TIR/2(=(+PEAK-(-PEAK))/2)
• Auto measurement start stop function

⑤ 5 ranks (-NG, -OK, OK, +OK, +NG) judgment is possible

Maximum of 99 ranks judgment is possible

⑥ Abundant external I/O functions

Serial communications function
To PC printer via RS232C
Measurement value and judgment result can be outputted. [Standard]

External button input function

[Standard]

Measurement command and master calibration command input is possible via foot switch
and push button.

Digimatic

output

function

[Optional]

Capable of outputting measurement value to Digimatic printer.

DC I/O function
Capable of outputting judgment result to the lamp sequencer and also BCD output of the
measurement value.

⑦ Compact

120(W) X 180 (D) X 150(H)mm, 300(D)mm when regulator is fitted

⑧ Accessories

• Handle for easily carrying

[Optional]

• Tuner

(dial)

cover

[Optional]

• Cable for each type of external I/O

[Optional]

Advertising