Blue-White CHEM-PRO C3 ProSeries Diaphragm Pump User Manual

Page 19

Advertising
background image

Page 18

Page 19

Chem-Pro

Chem-Pro

®

®

Used to manually control speed of pump.

Use UP and DOWN arrows to adjust speed while pump is running.

To select exact run speed, follow steps below.

Step 1

Ensure pump is stopped and LCD reads “OFF.”

Note: Mode cannot be changed while pump is in running.

Press and release STOP button if pump is running.
Press and release MODE button multiple times until Mode 1
is selected.

Step 2

With Mode 1 selected, press and hold MODE button until
‘Speed’ icon begins flashing.
This indicates that you’ve entered Setup menu.

Step 4

Pump will now operate at your pre-configured speed.
Press and release START button to start pump.

Press and release STOP button at anytime to stop pump.

With pump operating in manual mode (Mode 1), pump speed can be changed at anytime by using UP or DOWN arrows during
operation.

Mode 1

50.0

1

Mode 1

OFF

SPEED

1

SPEED

Step 3

Current pump speed will be displayed.
To increase value, press and release UP arrow.
To decrease value, press and release DOWN arrow.
To save value, press and hold MODE button until ‘Speed’
icon stop flashing.

Mode 1

50.0

1

SPEED

Mode 1

OFF

1

SPEED

8.0

Mode 1 - Manual Operation

8.1

Mode 1 - Manual Operation Screen Shots

Runtime Screen Shot 1

Display motor speed percentage.
Pump Running in Manual Operation

Runtime Screen Shot 2

Display 4-20mA output (select models only)
Press and release MODE button to view mA output value
in real-time.

Please note: 4-20mA output is only available on select models. If included in
your model; 4-20mA output must be enabled in Mode 0 (see page 16).

9.6

mA

1

35.0

1

SPEED

OUT

Runtime Screen Shot 3

Display motor speed percentage.
Press and release MODE button to view percentage of
motor speed.

35.0

1

SPEED

MODE

MODE

Advertising
This manual is related to the following products: