Used to remotely control pump with an incoming pulse signal. Can be used with an external foot pedal, a water
meter, a PLC, contact closure, or other low speed pulse devices.

Default setting: 1 Pulse = 100% motor speed for 2.5 seconds

Step 1

Ensure pump is stopped and LCD reads “OFF.”

Note: Mode cannot be changed while pump is in running.

Press and release STOP button if pump is running.
Press and release MODE button multiple times until Mode 2
is selected.

Step 2

With Mode 4 selected, press and hold MODE button until
‘On’ icon begins flashing.
This indicates that you’ve entered Setup menu.

Step 3

Pump on-time will be displayed in either MIN (minutes) or
SEC (seconds).
To increase value, press and release UP arrow.
To decrease value, press and release DOWN arrow.
To save value, press and release MODE button.

Step 5

Number of pulses to trigger pump start will be displayed.
To increase value, press and release UP arrow.
To decrease value, press and release DOWN arrow.
To save value, press and release MODE button.

Mode 4

Step 7

To exit Setup, press and hold MODE button for a few
seconds until you return to Run screen.

Default Setting

4

Step 6

Pump speed during on-time will now be displayed.
Pump will run at this speed after selected number of pulses
is reached from previous menu.
To increase value, press and release UP arrow.
To decrease value, press and release DOWN arrow.
To save value, press and release MODE button.

Mode 4

100.0

Mode 4

OFF

MIN

4

4

1

Step 4

MIN (minutes) or SEC (seconds) will be displayed in lower
right hand corner. This value will be linked to Pump on-time
number in previous screen.
To change this setting, press and release either UP arrow or
DOWN arrow.
To save value, press and release MODE button.

Mode 4

Mode 4

Mode 4

Mode 4

OFF

4

0

200 400 600 800 1000

0

25

50

75

100

Pump

Motor Speed (%)

Frequency Input (Hz)

0%

Output

100%

Output

Hz

ON

ON

Hz

100.0

MIN

4

ON

Hz

4

ON

Hz

SEC

Hz

ON

4

1.0

Hz

ON

SPEED

Hz

ON

11.0 Mode 4 - Pulse Batch (low speed pulse) Operation

11.0 Mode 4 - Pulse Batch (low speed pulse) Operation - Continued

MIN or

SEC

Runtime Screen Shot 1

Mode 4

11.1 Mode 4 - Pulse Batch Operation Screen Shots

Runtime Screen Shot 2

Mode 4

2

Hz

4

Display motor speed percentage.
Pump Running in Pulse Batch Operation

Display current number of pulses received
Press and release MODE button to view number of
pulses received in real-time.

35.0

SPEED

4

Runtime Screen Shot 3

Mode 4

9.6

mA

4

Press and release MODE button again to view mA output
value in real-time

(available on select models only)

.

Press and release MODE button again to view motor
speed percentage
, as in Screen Shot 1.

OUT

®

®

Chem-Pro

Chem-Pro

Time-out - Chem-Pro® pumps have a time-out setting of approximately 20 seconds while in configuration menu. If built-in timer
exceeds 20 seconds without a button being pressed, then pump will exit configuration menu. Changes will automatically be saved if
programming mode is allowed to Time-Out.

MODE

MODE

Only available on certain models

Advertising
This manual is related to the following products: