i?

(Inclinometer Update)

Description

Samples and returns the pitch and roll inclinometer data. When in Standby mode (h)
use this command to query the inclinometer readings regardless of whether
inclinometer data has been selected for inclusion in the output word.

Syntax

i?<cr>

Output

When the inclinometer units are set to degrees:

$P(-)nn.nR(-)nn.n[Ennn]*checksum<cr><lf>:<cr><lf>

When inclinometer units set to mils:

$P(-)nnnR(-)nnn[Ennn]*checksum<cr><lf>:<cr><lf>

Resolution

0.1° or 2 mils

Valid Values

0 to +80 ° or, 0 to +1421.6 mils

Example

i?<cr>

$P-30.0R-20.1[Ennn]*checksum<cr><lf>:<cr><lf>

Related Commands

ep= (Enable Pitch)

er= (Enable Roll)