Connecting the axis 700 to the network – Axis Communications Axis Network Scan Server 700 User Manual

Page 17

Advertising
background image

Section 2: Basic Installation

AXIS 700 User’s Manual

16

Connecting the AXIS 700 to the Scanning Device

Caution!

o Make sure that the power supply (AXIS PS-C, 12 V DC, 36VA or

AXIS PS-E, 12 V DC, 13,2VA) included in the delivery is marked
with the correct mains voltage.

o Always make sure that power is not connected to any of the units

when making changes to the SCSI chain. The SCSI bus may
become damaged if you connect or disconnect units when the
power is on.

To connect the AXIS 700 to your scanning device, follow these steps:

1. Connect the SCSI cable to the SCSI connector on the AXIS 700.

2. Connect the SCSI cable to the scanning device.

3. The AXIS 700 uses a built-in SCSI terminator.

Note:

o The scanning device must also be terminated properly. Refer to

the scanning device documentation on how to do this.

Connecting the AXIS 700 to the Network

Important!

o Always consult the Network Administrator before making

changes to the network configuration.

To connect the AXIS 700 to your network, follow these steps:

1. Turn off the AXIS 700 by unplugging the power supply.

2. Connect the network cable to the appropriate network connector,

i.e. RJ-45 for 10baseT and BNC for 10base2, respectively.

3. Power up the scanning device.

4. Connect the external power supply to the AXIS 700. The AXIS 700

LED indicators will flash during power up and self test.

Advertising