Appendix D: Updating the Software

AXIS 700 User’s Manual

90

Updating the Flash Memory

To upgrade over the network you will need the following:

The file with the new AXIS 700 software. The name of the file is
of the form

product-version.bin

, i.e.

700_1_14.bin

for

software release 1.14 of the AXIS 700.

A computer on the network with TCP/IP and FTP.

Follow these steps to upgrade the AXIS 700 software:

1. Log in to the AXIS 700 with the command

ftp <IP address>

where

<IP address>

is the name or IP address assigned to the

AXIS 700.

2. You will be prompted for user id and password. Use the user id

root

which has the default password

pass.

3. Issue the command

bin

to change to binary transfer mode.

4. Issue the command

put <software name> flash

where

<software name>

is the name of the new software, e.g.

700-

1_14.bin

.

5. During the flash load, the AXIS 700 LCD will display the message

Upgrading server

” and a progress bar. Wait for the flash load to

finish. This normally takes 1 to 4 minutes. The unit will then
automatically restart with the new AXIS 700 software.

Caution!

Be careful not to interrupt the file transfer. If the transfer is
interrupted, the AXIS 700 may have to be re-initialized by your
dealer.

6. Log out using the command

quit

,

bye

or

exit

depending on your

FTP version.

Notes:

o If you are using a window-based FTP client application such as

Ws_ftp or Fetch, you must rename the new file

<software

file>

to

flash

before downloading.

o It is recommended to upload the current configuration before

upgrading. SeeConfiguring using FTP” on page 51.