Spectrophotometer read error – Canon imagePROGRAF iPF6400S User Manual

Page 153

Advertising
background image

iPF6400S Basic Guide

153

Er

ror M

essa

ge

Me
ssa
ges
r

egar
ding
pr

inti
ng
or

a

djus
tm

ent

Spectrophotometer read error.

Cause

Corrective Action

The Spectrophotometer Sensor to
be loaded into the
Spectrophotometer Carriage is not
installed correctly.

Turn off the power, and reinstall by pushing the two connectors all the way into the
Spectrophotometer Sensor.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit
(option).")➔User's Guide

The color measurement pattern
was not printed correctly.

Check the color measurement pattern. If the printing is faint, clean the printhead and
perform the operation again.
(See "Cleaning the Printhead.")➔P.55

The color measurement pattern is
out of alignment.

Pulling or lifting a printed color measurement pattern may cause the pattern to come
out of alignment. Perform the operation again taking care not to touch the color
measurement pattern.

Execute Feed Priority to improve the printing position of the pattern for color
measurement.
(See "Automatic Banding Adjustment.")➔P.100

If the same message is displayed again after performing the above operation, set
Pattern Size to Large on the Control Panel menu and perform the operation again.
(See "Menu Structure.")➔P.66
Alternately, it may be resolved by selecting Air Drying in Drying Method in the
Color Measurement Preferences dialog box in the Color Calibration Management
Console and selecting the Dry Separated Chart check box if it is off.
(See "Acquiring Color Measurement Data For Any Color Chart (Windows).")➔User's
Guide

(See "Acquiring Color Measurement Data For Any Color Chart (Mac OS).")➔User's
Guide

The performance of part of the
Spectrophotometer Unit may be
impaired.

Turn off the printer and wait a while before restoring power, and then perform the
operation again.
If the same message is displayed again, contact your Canon dealer for assistance.

Clean calibration white tile because it may be dirty.

Cause

Corrective Action

The White Calibration Tile may be dirty.

Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")➔P.56

If this message is still displayed after cleaning the White Calibration Tile, we
recommend adjusting the Spectrophotometer Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit
(option).")➔User's Guide