Canon imagePROGRAF iPF6400S User Manual

Page 58

Advertising
background image

iPF6400S Basic Guide

58

C

ons

uma

bles
a

nd

M

ain

te

na

nc

e

C

le

an

in

g t

he

P

rint

er

7

Move the White Calibration Tile Holder in the
direction of the arrow and remove it from the
Up-down Unit.

Important

• Do not touch the (a) part of the White

Calibration Tile Holder except when

removing the White Calibration Tile.

Doing so may cause the White Calibration

Tile to fall, which can lead to damage.

8

Push the (a) part of the White Calibration Tile
Holder and remove the White Calibration Tile.

Important

• Never touch the white part of the White

Calibration Tile.

If the white part is dirty, the printer may

not be able to obtain the correct color

measurement results.

9

Wipe the surface of the White Calibration Tile clean with a dry, soft cloth.
If the white part is particularly dirty, use a damp cloth that you have wrung out completely to wipe
the surface of the White Calibration Tile clean and use a dry cloth to dry the surface.

10

Place the White Calibration Tile in the White
Calibration Tile Holder and mount it in the
position shown in the diagram while pushing
down on the (a) part.
When installing the White Calibration Tile, make
sure it is facing the appropriate direction.