2. Electrical Service Specifications

* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.
** IMPORTANT: In cases where fuses are used of the dual element type, time delay, current limit, class RK1

or RK5 ONLY.

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is

affixed to the left side panel area behind the top access (control) door. In the case of
208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to dryer

components due to improper voltage connections will automatically VOID THE
WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or

obligation.

MLG-82 II (Gas)

MLS-82 II (Steam)

ELECTRIC SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME . When ordering, specify exact voltage.

NOTES:

A.

Circuit breakers are thermal magnetic (industrial) motor valve type ONLY . For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.

B.

Circuit breakers for 3-Phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

MINIMUM

WIRE SIZE

CIRCUIT

BREAKER

AMPERAGE**

60 Hz

50 Hz

60 Hz

50 Hz

208

3

/4

12.4

--

*

25

--

240

3

12.4

16.4

*

25

30

380

-400

3

/4

--

7

.7

*

- -

15

416

3

/4

--

8.1

*

- -

15

460/480

3

/4

6.7

--

*

15

--