SECTION IX

BURNER and BASKET (TUMBLER)/LINT CHAMBER

MANUAL RESET HI-LIMIT INSTRUCTIONS

I M P O R T A N T

MANUAL RESET HI-LIMIT INSTRUCTIONS

FOR PHASE 6 MODELS

(GAS MODELS ONLY)

This dryer was manufactured with a burner manual reset hi-limit and basket (tumbler)/lint chamber hi-limit
thermostat which is monitored by the Phase 6 computer. If either manual reset thermostat is open prior to start
of the drying cycle, the dryer will start momentarily and then shutdown, the Phase 6 computer will display an error
code with an audio indication. If the basket (tumbler)/lint chamber hi-limit thermostat is open, the display will read
“dRUM SAFETY FAIL.” If the burner hi-limit thermostat is open, the display will read “bURNER SAFETY
FAIL.”

If either manual reset hi-limit thermostat opens during a drying cycle, the display will show the applicable error
code described above along with an audio indication. If the drum temperature is above 100° F (38° C), the dryer
will continue to run with no heat for 3 minutes or until the drum temperature has flattened below 100° F (38° C).
The “STOP/CLEAR” button on the Phase 6 keyboard (touch pad) must be pressed to clear the error condition.
The open manual reset hi-limit thermostat must be reset “manually” prior to the start of the next cycle.

This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner operation.

The location of the burner hi-limit is on the right side of the burner box and the basket (tumbler) hi-limit is located
in the lint chamber area.

WARNING: Discontinue power to dryer before attempting to reset hi-limit.

IMPORTANT

This dryer is equipped with a burner

hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.

WARNING:

Discontinue power to dryer

before attempting to reset hi-limit.