Installer menu (cont.) – LG 42LD6DDH User Manual

Page 114

Advertising
background image

19

206-4190

012 - IR BANKS EN (IR Banks Enable)

For direct access to a particular channel bank. When enabled, you

can access a channel bank by inputting the IR code for the bank.

013 - SCAN MODE (Functional after 2-5-5 + MENU transfer)

Allows variation in turning the TV ON/OFF with Channel Up/Down.

You may opt for TV channels only or TV channels + OFF/ON. If

set to 0, Channel Up/Down keys change channels only. If set to 1,

channel DOWN below the lowest channel or Channel UP above

the highest channel to turn the TV OFF.

014 - STRT CH IN SM (Start Channel in Scan Mode)

If set to 1, installs TV ON/OFF event below the start channel at

TV turn ON. If set to 1, the user can select channels with either

Channel Up/Down or by direct keypad entry. If set to 0, only those

channels that are entered for scanning can be selected.

015 - SLEEP TIMER

If set to 1, the Sleep Timer feature may be used. If set to 0, the

Sleep Timer is not available.

016 - EN TIMER (Enable On/Off Timers)

If set to 1, the Timer function is available to the end user and

enabled continuously. Set to 0 to disable On/Off timers.
Note: Clock must be set in order for timers to be used.

017 - ALARM

Gives the installer the option of making the Alarm function avail-

able to the end user. If set to 1, the Alarm function is available to

the end user. Set to 0 to disable the Alarm function.
Note: Clock must be set before the Alarm function will work.

020 - FEATURE LEVEL

For LG3DDH TVs, leave set to 1 (default) to enable Zenith IR

codes remote control operation.
For LD6DDH TVs, this item determines an additional IR code

scheme to which the TV will respond, allowing for the use of unique

IR codes based on “bed number” in a multi-TV single room installa-

tion. First determine the IR mode; then select the bed number.

IR Mode

Bed #

Values

Legacy (Hospital)

1 – 2

0 – 1

Multi-code Remote

1 – 9

16 – 24

Note: For further information, see documentation for the accessory

package that includes the multi-code remote.

021 - V-CHIP (Parental Control)

Set to 1 to activate V-Chip (Parental Control) and have it available

to the end user to filter and control or otherwise restrict program-

ming content that can appear. Set to 0 to turn the V-Chip feature

Off (not available to user); no programming restrictions can be set.

022 - MAX BLK HRS (Maximum Block Hours)

Sets hours from 0 to 99 for the maximum V-Chip (Parental Control)

block hours. Default setting is for 12 blocking hours.

023 - CAPTION LOCK

If set to 0, captions are OFF when the TV is turned ON. Set to 1 to

use the caption setting configured before the TV was turned OFF

when the TV is turned ON.

025 - FUNCTION PRE (Function Preview)

Set to 0 to suppress channel preview from the Function Menu, if

available (i.e., the TV is not in Stand-alone Mode).

027 - HOSPITAL MODE

With this setting two things are affected: Channel Banks 1, 2, and

3 are accessible, while Channel Bank 4 can be made inactive by

removing all the channels from Channel Bank 4. Then, if Channel

Bank 4 is selected when the TV is turned ON, the TV screen will

show “Inactive TV.” The Channel Bank 4 setup allows the hospital

to present TV viewing options to the patient. The patient can select

programming options available in Channel Banks 1, 2, or 3. Chan-

nel Banks are available in all Hospital Modes (1, 2, etc.).
The IR code that will control the TV depends on the Installer Menu

item 020 FEATURE LEVEL setting.
Set according to the pillow speaker supply voltage and audio

source (see table below). Note the following regarding pillow speak-

er voltage: +12 v identifies a Zenith pillow speaker, +5 v identifies a

Phillips pillow speaker, and -5 v identifies an RCA pillow speaker.
Note: The default setting (254) is not selectable in the Installer

Menu. If you ever need to restore the default setting, you must set

item 117 FACT DEFAULT to 1 to reload the factory default settings.

See item 117 description for further information.

Item

027

Value

Hospital Mode

Pillow

Speaker

Voltage

Audio Source

(Switch = Pillow)

000

Disabled

+12 v

Pillow Only

001

Enabled, Zenith Private Label

+12 v

Pillow Only

002

Enabled, Zenith Consumer

+12 v

Pillow Only

017

Enabled, Zenith Private Label

+5 v

Pillow Only

018

Enabled, Zenith Consumer

+5 v

Pillow Only

033

Enabled, Zenith Private Label

-5 v

Pillow Only

034

Enabled, Zenith Consumer

-5 v

Pillow Only

065

Enabled, Zenith Private Label

+12 v

Main Only

066

Enabled, Zenith Consumer

+12 v

Main Only

081

Enabled, Zenith Private Label

+5 v

Main Only

082

Enabled, Zenith Consumer

+5 v

Main Only

097

Enabled, Zenith Private Label

-5 v

Main Only

098

Enabled, Zenith Consumer

-5 v

Main Only

129

Enabled, Zenith Private Label

+12 v

Pillow & Main

130

Enabled, Zenith Consumer

+12 v

Pillow & Main

145

Enabled, Zenith Private Label

+5 v

Pillow & Main

146

Enabled, Zenith Consumer

+5 v

Pillow & Main

161

Enabled, Zenith Private Label

-5 v

Pillow & Main

162

Enabled, Zenith Consumer

-5 v

Pillow & Main

254

Enabled, Zenith Consumer

0 v

Main Only

Installer Menu (Cont.)

Advertising