6. FUNCTION PARAMETER SETTINGS

To design a platform scale, set the capacity, weighing
unit and other functions according to the specifications
of the scale.
Normally, end users do not have to set these function
parameters and these setting can be sealed together
with the calibration switch.

6-1. The procedure for setting parameters

‰

Do not set “C01-1”. Once set, the indicator cannot get into the parameter

setting procedure again.

‰

When turning the power on and the indicator may display ------- ,

press the

PRINT/ENT

key to proceed to the weighing mode.

‰

See “7. CALIBRATION” as for the location of the calibration (CAL) switch.

1. In the weighing mode, press and hold the calibration (CAL)

switch until

Cal

appears. Then, release the switch.

‰

Press and hold the

0

key for about 5 seconds, then you

can also enter the calibration mode

(when “C01-0” is set).

‰

Press the

ON/OFF

key or (CAL) switch to stop the

setting procedure.

2. Press and hold the

ZERO

key and press the

PRINT/ENT

key. Then the first function number is

displayed.

3. Press the

2

key to enter into the “C02 Capacity”

setting.

4. Press the

PRINT/ENT

key. Then the parameter

stored appears.

5. Enter the parameter value for the capacity using the

10-key pad.

6. Press the

ZERO

key to go to the next function

number “C03 Weighing display unit”.

7. Set C03 “0” (metric unit), or “1” (non-metric unit).

8. The settings C02 and C03 are minimum requirements

to design a platform scale. To finalize the settings, be
sure to press the

PRINT/ENTER

key. Then, the

display shows

end

for a few seconds and

returns to weighing mode.

‰

The

ZERO

key increments the function number as in the step 6 above, but note

that all of the new parameters are not stored until

end

is displayed.

‰

To exit with nothing changed, turn the power off without pressing the

PRINT/ENT

key.

‰

Set the other parameters according to the specifications required.

-

C01-

01

Parameter

Function number

-

C01-

0

0

-

C02-

0

0

-

C02-

01

-

C02-

0

2

-00

Cal

00

-

C03-

0

1

-00

end