Fon ^gdi ^giv ^glh – AMX Modero NXD-CV5 User Manual

Page 116

Advertising
background image

Programming

104

NXD-CV5 5" Modero Wall/Flush Mount Touch Panel

"^" Button Commands (Cont.)

^FON

Set a font to a
specific Font ID
value for those
buttons with a
defined address
range.

Font ID numbers are generated by the TPDesign4 programmers report.
Syntax:

"'^FON-<vt addr range>,<button states range>,<font value>'"

Variable:

variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
font value = Range = 1 - XXX. Refer to theDefault Font Styles and ID Numbers table on
page 90.

Example:

SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"

Sets the font size to font ID #4 for the On and Off states of buttons with the variable text
range of 500-504 & 510-515.
Note: The Font ID is generated by TPD4 and is located in TPD4 through the Main menu.
Panel > Generate Programmer's Report >Text Only Format >Readme.txt.

^GDI

Change the
bargraph drag
increment.

Syntax:

"'^GDI-<vt addr range>,<bargraph drag increment>'"

Variable:

variable text address range = 1 - 4000.
bargraph drag increment = The default drag increment is 256.

Example:

SEND_COMMAND Panel,"'^GDI-7,128'"

Sets the bargraph with variable text 7 to a drag increment of 128.

^GIV

Invert the
joystick axis to
move the origin to
another corner.

Parameters 1,2, and 3 will cause a bargraph or slider to be inverted regardless of
orientation. Their effect will be as described for joysticks.
Syntax:

"'^GIV-<vt addr range>,<joystick axis to invert>'"

Variable:

variable text address range = 1 - 4000.
joystick axis to invert = 0 - 3.

For a bargraph 1 = Invert , 0 = Non Invert
Example:

SEND_COMMAND Panel,"'^GIV-500,3'"

Inverts the joystick axis origin to the bottom right corner.

^GLH

Change the
bargraph upper
limit.

Syntax:

"'^GLH-<vt addr range>,<bargraph hi>'"

Variable:

variable text address range = 1 - 4000.
bargraph limit range = 1 - 65535 (bargraph upper limit range).

Example:

SEND_COMMAND Panel,"'^GLH-500,1000'"

Changes the bargraph upper limit to 1000.

0

2

3

1

1 = Invert horizontal axis

2 = Invert vertical axis
3 = Invert both axis locations

0 = Normal