Pre-wall installation of the rough-in box – AMX Modero NXD-CV5 User Manual

Page 28

Advertising
background image

Installation

16

NXD-CV5 5" Modero Wall/Flush Mount Touch Panel

d.

Firmly press down around the Button Trim Ring until all of the latches are securely inserted into their

openings on the Faceplate, and the Button Trim Ring is securely fastened. Verify the Button Trim
Ring is firmly inserted onto the Faceplate and that there are no gaps between this Trim Ring and the
outer surface of the Faceplate.

e.

Continue on to Step 4 to complete the installation process.

To assemble the Bezel Kit with No-Buttons (FIG. 15):

a.

Grasp the provided No-Button Trim Ring on both sides and fit it into the groove along the outside

surface of the Faceplate.

b.

Firmly press down around the No-Button Trim Ring until all of the latches are securely inserted into

their openings on the Faceplate, and the Trim Ring is securely fastened. Verify the No-Button Trim
Ring is firmly inserted onto the Faceplate and that there are no gaps between this Trim Ring and the
outer surface of the Faceplate.

c.

Continue on to Step 4 to complete the installation process.

4.

Place that new Faceplate onto the main NXD-CV5 unit. Make sure to align the Microphone, Light, and
PIR Motion sensor locations on the main unit to their respective openings on the Faceplate assembly.

Pre-Wall Installation of the Rough-In Box

Wall Mount panels (NXDs) are contained within an outer housing (back box). This back box is not removed
when installing the NXD into a CB-TP5 Rough-In Box. The back box is only removed to gain access for the
replacement of the internal components.

The CB-TP5 is an optional metallic box that is secured onto a stud/beam in a pre-wall setting (where no walls
are present
). Installation procedures and configurations can vary depending on the installation environment.
This section describes the installation procedures for the most common installation scenario. The most
important thing to remember when mounting this rough-in box is that the NXD-CV5 Mounting Tabs must lie
flush against the outside of the sheetrock (FIG. 16).

Refer to SP-2261-01 for detailed installation dimensions.

It is recommended that you cut out the surface slightly smaller than what is outlined in the
installation drawings so that you can make any necessary cutout adjustments.

The wiring knockouts on the left side will be used for the NXD-CV5 Wall Mount panel connectors,

so always secure the rough-in box to the stud using the Stud Mounting Holes on the right side of
the box.

FIG. 15

Installing the No-Button Bezel Kit (NXA-BEZ-5NB)

No-Button Trim Ring

Faceplate (outer surface shown)

Hollow button openings

INSTALLER: LEAVE A GAP BETWEEN THE STUD AND ROUGH-IN BOX
MOUNTING TABS TO ACCOMMODATE THE DRYWALL or SHEETROCK.
This gap allows the installation of the drywall or sheetrock after the CB-TP5 Rough-In
Box has been installed.

Advertising