Upgrading Modero Firmware

51

NXD-CV5 5" Modero Wall/Flush Mount Touch Panel

The panel will not appear as a device below the virtual system number (in the Online Tree tab) until
both the system number used in step 7 for the Virtual NetLinx Master (VNM) is entered into the Master
Connection section of the System Connection page and the panel is restarted.

Step 3: Confirm and Upgrade the firmware via the USB port

Use the CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) to provide communication
between the mini-USB Program port on the touch panel and the PC. This method of communication is used to
transfer firmware Kit files and TPD4 touch panel files.

1.

Verify this direct USB connection (Type-A on the panel to mini-USB on the panel) is configured properly
using the steps outlined in the previous two sections.

2.

With the panel already configured for USB communication and the Virtual Master setup within NetLinx
Studio, its now time to verify the panel is ready to receive files.

3.

After the Communication Verification dialog window verifies active communication between the Virtual
Master and the panel, click the OnLine Tree tab in the Workspace window (FIG. 48) to view the devices
on the Virtual System. The default System value is one.

4.

Right-click on the System entry (FIG. 48) and select Refresh System to re-populate the list.
Verify the panel appears in the OnLine Tree tab of the Workspace window.
The default Modero panel value is 10001.

5.

If the panel firmware being used is not current, download the latest Kit file by first logging in to
www.amx.com and then navigate to Tech Center > Firmware Files and from within the Modero section
of the web page locate your Modero panel.

6.

Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you have
downloaded the Modero Kit file to a known location.

If the G4 panel does not appear, refer to the Troubleshooting section on page 135 for
more information.

A mini-USB connection is only detected after it is installed onto an active panel.
Connection to a previously powered panel which then reboots, allows the PC to
detect the panel and assign an appropriate USB driver.

FIG. 48

NetLinx Workspace window (showing the panel connection via a Virtual NetLinx Master)

The Virtual Master firmware
version and device number

Showing the current Modero
panel firmware version and
device number

NetLinx Studio version number

The panel firmware is shown on the right of the listed panel.
Download the latest firmware file from www.amx.com and then save the Kit file to
your computer.