Installation

19

NXD-CV5 5" Modero Wall/Flush Mount Touch Panel

6.

Carefully slide the main NXD-CV5 unit (B in FIG. 17) into the rough-in box, so that all Mounting Tabs
lie flush against the rough-in box (C in FIG. 17).

7.

Insert and secure three #4-40 Mounting Screws (included) into their corresponding holes located along
the sides of the NXD.

8.

Place the Faceplate/Trim Ring (A in FIG. 17) back onto the main NXD unit (B in FIG. 17).
Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings
on the front faceplate/bezel.

9.

Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective
locations (outside the rough-in box) on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port,
or NetLinx Master.

10.

Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

Installing the NXD into drywall using Expansion Clips

Expansion clips are mounted through the three oval holes located along the rim of the NXD-CV5. As the screw
is tightened, the clip bends toward the insertion hole and into the wall. This bending creates a "grip" on the
wall by either pressing onto the wall or by securing the drywall between the housing and the drywall clip.

The most important thing to remember when mounting the NXD is that the outer frame (Mounting Tabs) must
be installed flush against the mounting surface.

Refer to SP-2261-02 for detailed installation dimensions (reproduced in FIG. 18).

It is recommended that you cutout the surface slightly smaller than what is outlined in the
installation drawings so that you can make any necessary cutout adjustments.

1.

Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.

2.

Cut out the surface for the NXD Wall Mount unit.

If installing the panel into a pre-existing wall or surface, place and secure the pre-printed Mounting

Template for Flush Mount Drywall Installation (62-2261-10) onto the surface.

Trace the required cutout along the drywall. Refer to the dimensions in FIG. 18 for more
information.

3.

Remove the Faceplate/bezel (A in FIG. 19) from the main NXD unit (B in FIG. 19) by gripping the
faceplate and pulling with gentle outward force.

It is recommended that the actual cutout opening be slightly smaller than the
provided dimensions. This action provides the installer with a margin for error if the
opening needs to later be expanded.
Be sure to cut out the three notches along the sides to accommodate the three
corresponding drywall expansion clips (included within the Installation Kit).