Configuring Communication

33

NXD-CV5 5" Modero Wall/Flush Mount Touch Panel

Configuring and Using USB with a Virtual Master

NetLinx Studio can be setup to run a Virtual Master where the PC acts as the Master by supplying its own IP
Address for communication to the panel. The PC is first equipped with the USB driver, the panel is then
configured for USB communication, and then Studio is configured to act as the Master.

For a personal computer to establish a connection to a Modero panel via USB, the target computer must have
the appropriate AMX USB driver installed. This installation is bundled into the latest TPDesign4 software
setup process or can be downloaded independently from the main Application Files page on www.amx.com.

Step 1: Setup the Panel and PC for USB Communication

1.

If you do not currently have the latest version of TPDesign4, navigate to www.amx.com > Tech Center >
Downloadable Files > Application Files > NetLinx Design Tools section of the website and locate the
AMX USB Driver executable (AMX USBLAN Setup exe).

2.

Download this executable file to a known location on your computer.

3.

Launch the Setup.exe and follow the on-screen prompts to complete the installation.

Step 2: Confirm the Installation of the USB Driver on the PC

The first time each AMX touch panel is connected to the PC it is detected as a new hardware device and the
USBLAN driver becomes associated with it (panel specific). Each time thereafter the panel is "recognized" as
a unique USBLAN device and the association to the driver is done in the background. When the panel is
detected for the first time some user intervention is required during the association between panel and driver.

1.

After the installation of the USB driver has been completed, confirm the proper installation of the large
Type-A USB connector to the PC's USB port, and restart your machine.

2.

Connect the terminal end of the 12 VDC-compliant power supply cable to the power connector on the
rear/side of the touch panel and then apply power.

3.

After the CV5 panel powers-up, press and hold the grey Front Setup Access button (for 3 seconds) to
continue with the setup process and proceed to the Setup page.

4.

Select Protected Setup > System Connection (located on the lower-left) to open the System Connection
page (FIG. 32).

5.

Toggle the blue Type field (from the Master Connection section) until the choice cycles to USB. Refer to
the System Settings Page section on page 68 for more information about the fields on this page.

The mini-USB connector MUST be plugged into an already active panel before the
PC can recognize the connection and assign an appropriate USB driver. This driver is
part of both the NetLinx Studio and TPDesign4 software application installations.

If the panel is already powered, continue with steps 3.
The panel MUST be powered and configured for USB communication before
connecting the mini-USB connector to the panel’s Program Port.

FIG. 32

USB System Connection page - using a USB Connection Type

No connection is established until
the Virtual Master becomes
active within Studio

Red

Connection Status icon -

Green

Connection Status icon -

indicates no connection to a Virtual

indicates communication to a Virtual

Master

Master

Advertising