AMX Modero NXD-CV5 User Manual

Page 79

Advertising
background image

Firmware Pages and Descriptions

67

NXD-CV5 5" Modero Wall/Flush Mount Touch Panel

Protected Setup Page Elements (Cont.)

Options:

Allows you to select various touch panel features:
• The Function Show button enables the display of the channel port and

channel code in the top left corner of the button, the level port and level code
in the bottom left corner, and the address port and address code in the
bottom right corner (see FIG. 64 for an example of the function locations).

• Use the Page Tracking button to toggle page tracking. When enabled, the

touch panel sends page data back to the NetLinx Master, or vice versa
depending on the touch panel settings.

• Use the Telnet button to enable or disable the telnet server on the panel. This

feature focuses on direct telnet communication to the panel.

• Use the Front Button Setup Access button to activate the grey Front Setup

Access button (located below the LCD) to access the firmware pages.
- Default condition is On.
- Press and hold this grey button for 3 seconds to access the Setup page.
- Press and hold this grey button for 6 seconds to access the Calibration
page.

Reboot Panel:

Pressing this button causes the panel to restart after saving any changes.

System Recovery:

Allows you to either reset the touch panel to factory default settings and/or wipe
out all existing touch panel pages:
• The Reset System Settings button allows a user to wipe out all current

configuration parameters on the touch panel (such as IP Addresses, Device
Number assignments, Passwords, and other presets).
- Pressing this button launches a Confirmation dialog (FIG. 63) which asks
you to confirm your selection.
- This dialog is configured with a delay timer that does not enable the YES
button for 5 seconds. This delay provides an additional amount of time for
the user to confirm their decision.

• The Remove User Pages button allows you remove all current TPD4 touch

panel pages currently on the panel (including the pre-installed AMX Demo
pages
).
- Pressing this button launches a Confirmation dialog (FIG. 63) which asks
you to confirm your selection.
- This dialog is configured with a delay timer that does not enable the YES
button for 5 seconds. This delay provides an additional amount of time for
the user to confirm their decision.

FIG. 63

Protected Setup page-System Recovery confirmation dialog

You have a wait time of 5 seconds
before the YES option is enabled.

Advertising