Fork function failed” message on aix hosts, Known driver issues, Known device issues – HP Storage Essentials NAS Manager Software User Manual

Page 725: 146 known device issues

Advertising
background image

Storage Essentials 5.1 User Guide 693

“Fork Function Failed” Message on AIX Hosts

If a CIM Extension running on AIX detects low physical or virtual memory while starting, a “Fork

Function Failed” message appears. A CIM Extension on AIX uses additional memory and CPU

resources at start time. If the resources on the AIX machine is already low, you may see the “Fork

Function Failed” message. Depending on the AIX operating system or hardware, the host may crash

after you see this message.

Known Driver Issues

If you are having problems with a driver, keep in mind the following:

The software requires the driver to have a compliant SNIA HBA API. Emulex driver version 4.21e

does not support the SNIA HBA API.

If the driver has a compliant SNIA HBA API, make sure the driver is installed correctly.

Known Device Issues

The following table provides a description of the known device issues. You can find the latest

information about device issues in the release notes.

Table 146

Known Device Issues

Device

Software

Description

AIX host

NA

If you are receiving replication errors for an AIX host, the provider

may be trying to connect to the host using the 0.0.0.0 IP address

instead of the real host IP address. If this situation is occurring, you

would see a message containing the following when you start the

CIM Extension:

CXWS 3.1.0.144 on 0.0.0.0/0.0.0.0 now accepting
connections

To fix this situation, add the following line to the
/opt/APPQcime/tools/start file on the AIX host:

export NSORDER=local,bind

Advertising