Swapi setting through a proxy, Swapi, Setting through a – HP Storage Essentials NAS Manager Software User Manual

Page 82: Proxy

Advertising
background image

Discovering NAS Devices, Tape Libraries, Switches and Storage Systems

50

• If you discovered Connectrix Manager or EFC Manager, only enable SNMP trap forwarding

to the management server on the Connectrix Manager or EFC Manager, not on the

individual switches.Connectrix Manager or EFC Manager should be configured to forward

SNMP traps to the IP address of the management server, and the community string should

match the user ID you used to discover Connectrix Manager or EFC Manager.

• If you discovered Connectrix or McDATA switches directly, enable SNMP trap forwarding on

the switches, not on any other management software. The switches should be configured to

forward SNMP traps to the IP address of the management server, and the community string

should match the user ID you used to discover the Connectrix or McDATA switches.

SWAPI Setting Through a Proxy

With the SWAPI setting, the management server contacts a proxy to obtain information about the

switches connected to it. Use Enterprise Fabric Connectivity (EFC) Manager for this option. If you do

not have EFC Manager, see

SNMP Setting Through a Proxy

” on page 52. EFC Manager versions

7.0, 1.3 and later can communicate with the management server and the switch. EFC Manager

accesses the switch through a SWAPI connection. This configuration lets multiple instances of the

management server or other clients contact EFC Manager, which in turn provides information about

the switch.

IMPORTANT:

EMC customers using the EMC Connectrix Manager (EMC’s rebranded EFCM)

cannot use the EMC Fibre Zone Bridge (EMC’s rebranded Bridge Agent) to discover EMC switches

using SWAPI. The McDATA SWAPI library is incompatible with EMC’s Fibre Zone Bridge Agent.

If the Fibre Zone Bridge Agent is not installed or not needed, you can uninstall the Fibre Zone Bridge

Agent and install McDATA’s Bridge Agent. The McDATA Bridge Agent will work with EMC’s

Connectrix Manager, but it cannot co-exist with EMC’s Fibre Zone Bridge Agent.

If you are running Connectrix Manager and you need to have the EMC Fibre Zone Bridge Agent

running, you are not able to discover EMC switches using SWAPI. You must discover them through

the SNMP provider, either directly or through a proxy. See ”

SNMP Setting Through a Proxy

” on

page 52 for more information about using the SNMP provider to discover switches through a proxy.

See

Contacting a McDATA or Connectrix Switch Directly

” on page 55 for more information about

discovering switches by their IP address.

NOTE:

Neither McDATA nor EMC officially support running the EMC Connectrix Manager with

the McDATA Bridge Agent. Although this configuration has been tested for discovering EMC

switches using SWAPI, you should check with your EMC or McDATA representative to determine the

implications of this configuration.