HP StorageWorks EVA Controller HSG V8.8 Software User Manual

Page 62

Advertising
background image

Interpreting Agent Email Messages

62

Command Console V2.5 User Guide

0—Everything is fine.
1—Battery state went from bad to good.
2—Battery state went from good to bad.

The details of the battery failure follow in parentheses, in the format:

controller_id:state

where

controller_id

is the SCSI ID of the reporting controller (in other words,

the cache battery failed for the other controller), and

state

is one of the

following:

Good—Battery is good.
Low—Battery voltage is low.
Fail—Battery has failed.

In this example, the cache battery for the controller with SCSI ID 6 failed.

The Sixth Digit of the State Change Field (Temperature)

The sixth digit of the state change field reports temperature state changes.

Example:

WARNING: -
Suncity HSG80 10000200000 HSG80 temp(0:2:2) (SP_MONITOR:
Monitor_Subsys)

The sixth digit can have one of three values:

0—Everything is fine.
1—Temperature state went from bad to good.
2—Temperature state went from good to bad.

The details regarding the temperature change follow in parentheses, in the format:

cabinet_number:sensor_type:state

where

cabinet_number

is the cabinet ID from 0-1,

sensor_type

is the EMU

sensor (sensor 1 or sensor 2), and

state

is either of the following:

1—Temperature went from bad to good.
2—Temperature went from good to bad.

In this example, an adverse temperature change is detected by sensor 2 of the
main cabinet.

Advertising