HP StorageWorks EVA Controller HSG V8.8 Software User Manual

Page 65

Advertising
background image

Interpreting Agent Email Messages

65

Command Console V2.5 User Guide

The details about the failure of the LUN follow in parentheses, in the format:

virtual_disk:state

where

virtual_disk

is the unit number of the virtual disk and

state

is any of the

following:

0—Good.
1—Reduced.
2—Reconstructing.
3—Failed.

In this example, logical unit D100 failed.

In most cases, the RaidManager sends at least two consecutive email messages.
The first message is always in the form:

---------------
From RaidManager Tue Oct 6 16:09:37 1998
Date: Tue, 6 Oct 1998 16:09:37 -0500 (EST)
From: RaidManager

This is an automatic message from your StorageWorks
RAID Agent, steamd. The following message was just received.
Please check your syslog files and RAID box!

Hostname: Suncity

WARNING: - A RAID system change has been detected: Suncity HSG80
OVRL=1 (SP_MONITOR: MonitorSubsys)

End Of Automatic Message.
-------------

The text of the second message will be similar to the following (depending on the
error):

---------
From RaidManager Tue Oct 6 16:09:37 1998
Date: Tue, 6 Oct 1998 16:09:37 -0500 (EST)
From: RaidManager

This is an automatic message from your StorageWorks
RAID Agent, steamd. The following message was just received.
Please check your syslog files and RAID box!

Hostname: Suncity

WARNING: - Suncity HSG80 12000000000 HSG80 disks(disk10200:1
disk10300:2) (SP_MONITOR: MonitorSubsys)

End Of Automatic Message.
-------------

Advertising