Translating event codes, Translating event codes –18, Example – HP Array Controller HSG V8.7 Software User Manual

Page 172

Advertising
background image

4–18

HSG80 User’s Guide

n

FULL displays additional information, such as the I960 stack and
hardware component register sets (for example, the memory
controller, FX, host port, and device ports, and so on).

4. Exit FMU with the following command:

EXIT

Example

The following example shows a last-failure entry. The Informational
Report—the lower half of the entry—contains the instance code,
reporting component, and so forth that you can translate with FMU to
learn more about the event.

Last Failure Entry: 4. Flags: 006FF300
Template: 1.(01) Description: Last Failure Event
Power On Time: 0. Years, 14. Days, 19. Hours, 51. Minutes, 31. Seconds
Controller Model: HSG80
Serial Number: AA12345678 Hardware Version: 0000(00)
Software Version: V082G(50)
Informational Report
Instance Code: 0102030A Description:
An unrecoverable software inconsistency was detected or an intentional
restart or shutdown of controller operation was requested.
Reporting Component: 1.(01) Description:
Executive Services
Reporting component’s event number: 2.(02)
Event Threshold: 10.(0A) Classification:
SOFT. An unexpected condition detected by a controller software com-
ponent (e.g., protocol violations, host buffer access errors, internal
inconsistencies, uninterpreted device errors, etc.) or an intentional
restart or shutdown of controller operation is indicated.
Last Failure Code: 20090010 (No Last Failure Parameters)
Last Failure Code: 20090010 Description:
This controller requested this controller to shutdown.
Reporting Component: 32.(20) Description:
Command Line Interpreter
Reporting component’s event number: 9.(09)
Restart Type: 1.(01) Description: No restart

Translating Event Codes


Use the following steps to translate the event codes in the fault-
management reports for spontaneous events and failures:

1. Connect a local terminal to the controller’s maintenance port.

2. Start FMU with the following command:

RUN FMU