Solid ocp patterns, Table c–1 solid ocp patterns (continued) – HP Array Controller HSG V8.7 Software User Manual

Page 427

Advertising
background image

LED Codes

C–3

Solid OCP Patterns

Table C–1

Solid OCP Patterns

Pattern

OCP

Code

Error

Repair Action

■● ● ● ●● ●

3F

DAEMON diagnostic failed hard
in non-fault tolerant mode

DAEMON diagnostic detected
critical hardware component
failure; controller can no longer
operate

Verify that cache module is present. If
the error persists, replace controller.

■● ● ● ●❍ ●

3D

NVPM structure revision greater
than image’s

NVPM structure revision number
is greater than the one that can be
handled by the software version
attempting to be executed

Replace program card with one that
contains the latest software version

■● ● ● ●❍ ❍

3C

NVPM write loop hang

Attempt to write data to NVPM
failed

Replace controller

■● ● ● ❍ ● ●

3B

NVPM read loop hang

Attempt to read data from NVPM
failed

Replace controller

■● ● ● ❍ ● ❍

3A

An unexpected NMI occurred
during Last Failure processing

Last Failure processing interrupted
by a Non-Maskable Interrupt
(NMI)

Reset controller

■● ● ● ❍ ❍ ●

39

NVPM configuration inconsistent

Device configuration within the
NVPM is inconsistent

Reset controller

Advertising