HP Array Controller HSG V8.7 Software User Manual

Page 474

Advertising
background image

D–40

HSG80 User’s Guide

01160108

The I960 reported a machine fault (parity error).

n

Last Failure Parameter [0] contains the RESERVED value.

n

Last Failure Parameter [1] contains the access type value.

n

Last Failure Parameter [2] contains the access address value.

n

Last Failure Parameter [3] contains the number of faults value.

n

Last Failure Parameter [4] contains the PC value.

n

Last Failure Parameter [5] contains the AC value.

n

Last Failure Parameter [6] contains the fault type and subtype values.

n

Last Failure Parameter [7] contains the RIP value.

01170108

The I960 reported a machine fault (parity error) while an NMI was being processed.

n

Last Failure Parameter [0] contains the RESERVED value.

n

Last Failure Parameter [1] contains the access type value.

n

Last Failure Parameter [2] contains the access address value.

n

Last Failure Parameter [3] contains the number of faults value.

n

Last Failure Parameter [4] contains the PC value.

n

Last Failure Parameter [5] contains the AC value.

n

Last Failure Parameter [6] contains the fault type and subtype values.

n

Last Failure Parameter [7] contains the RIP value.

01180105

A machine fault (parity error) occurred during EXEC$BUGCHECK processing.

n

Last Failure Parameter [0] contains the executive flags value.

n

Last Failure Parameter [1] contains the RIP from the machine fault stack.

n

Last Failure Parameter [2] contains the read diagnostic register 0 value.

n

Last Failure Parameter [3] contains the FX Chip CSR value.

n

Last Failure Parameter [4] contains the SIP last failure code value.

011B0108

The I960 reported a machine fault (nonparity error).

n

Last Failure Parameter [0] contains the Fault Data (2) value.

n

Last Failure Parameter [1] contains the Fault Data (1) value.

n

Last Failure Parameter [2] contains the Fault Data (0) value.

n

Last Failure Parameter [3] contains the Number of Faults value.

n

Last Failure Parameter [4] contains the PC value.

n

Last Failure Parameter [5] contains the AC value.

n

Last Failure Parameter [6] contains the Fault Flags, Type and Subtype values.

n

Last Failure Parameter [7] contains the RIP value (actual).

Table D–3

Last Failure Codes (Continued)

Code

Description

Advertising