HP Array Controller HSG V8.7 Software User Manual

Page 259

Advertising
background image

Upgrading the Subsystem

6–13

4. Start HSUTIL with the following command:

RUN HSUTIL

HSUTIL displays the following:

HSUTIL Main Menu:

0. Exit

1. Disk Format

2. Disk Device Code Load

3. Tape Device Code Load

4. Disaster Tolerance Backend Controller Code Load

Enter function number: (0:4) [0]?

5. Enter option 2, Disk Device Code Load, from the HSUTIL menu.

6. Choose the single-disk unit as the source disk for the download.

7. Enter the starting LBN of the firmware image—usually LBN 0.

8. Enter the product ID of the device you want to upgrade. This ID

corresponds to the product information that’s reported in the Type
column when you issue the SHOW DISK FULL command.

HSUTIL lists all devices that correspond to the product ID you entered.

9. Enter the disk or tape name of the device you want to upgrade.

10. Confirm or enter the byte count of the firmware image.

11. Confirm the download.

12. Some disk firmware releases require that you reformat the disk after

upgrading its firmware. See the documentation that accompanied the
firmware to determine if you need to reformat the device.

13. When HSUTIL finishes downloading the firmware, it displays the new

firmware revision for the disk drive.